BUENA INFORMACIÓN. MÁS TRANQUILIDAD.English

Indoor - Whirlpool/Spa · Waterloo Region

Westview Apartments (The)

201 - 55 Green Valley Dr, Kitchener

Última inspección: 9 jun 2026 · Ver en inglés

Requiere nueva inspección

Historial de inspecciones

9 jun 2026 · Compliance Inspection
Requiere nueva inspección
  • No grave Redacción oficial (en inglés): Pool, deck, equipment, sanitary facility and adjoining areas kept in a safe and sanitary manner and free from hazards
    Nota del inspector (en inglés): Not in Compliance: Maintain deck and deck surfaces free from hazards or hazardous obstructions, Maintain wall surfaces free from hazards or hazardous obstructions, Maintain wall surfaces in a sanitary condition - clean and sanitize wall surfaces
  • No grave Redacción oficial (en inglés): Manual chemical testing in compliance
    Nota del inspector (en inglés): Not in Compliance: Automatic Sensing Device - Ensure pH, alkalinity, Free Available Chlorine, total chlorine or bromine residuals and water clarity are tested manually one half hour before bathers are admitted, and checked at least every 4 hours during the operating day
18 feb 2026 · Compliance Inspection
Se encontraron infracciones
  • No grave Redacción oficial (en inglés): Caution notice(s) requirements met
    Nota del inspector (en inglés): Corrected During Inspection: Indicate the maximum number of bathers (the lesser of: one person per square metre of surface water OR the load identified by the manufacturer of the spa)
  • No grave Redacción oficial (en inglés): Total alkalinity is between 60 mg/L (60 ppm) and 180 mg/L (180 ppm)
    Nota del inspector (en inglés): Not in Compliance: Maintain total alkalinity between 60mg/L (60ppm) and 180 mg/L (180 ppm)
11 sept 2025 · Compliance Inspection
Se encontraron infracciones
  • Grave Redacción oficial (en inglés): Sanitizer levels in compliance
    Nota del inspector (en inglés): Not in Compliance: Maintain Total Bromine between 5mg/L (5ppm) - 10mg/L (10ppm)
23 jun 2025 · Compliance Inspection
Sin infracciones

No se registraron infracciones en esta inspección.

15 ene 2025 · Compliance Inspection
Requiere nueva inspección
  • No grave Redacción oficial (en inglés): Caution notice(s) requirements met
    Nota del inspector (en inglés): Not in Compliance: Ensure a caution notice is posted in a conspicuous location at each entrance to the spa, Ensure the word "CAUTION" is written in letters not less than 50 mm high with a stroke not less than 10 mm, Provide the correct wording not less than 10 mm high with a 5mm stroke: "Children under 12 are not allowed in the spa unless supervised by a person who is 16 years of age or older" , Provide the correct wording not less than 10 mm high with a 5mm stroke: "Pregnant women and persons with known health or medical conditions should consult with a physician before using a spa" , Provide the correct wording not less than 10 mm high with a 5mm stroke: "Do not use the spa if you have an open sore or rash, or are experiencing nausea, vomiting or diarrhea" , Provide the correct wording not less than 10 mm high with a 5mm stroke: "Overexposure may cause fainting. 10 to 15 minutes may be excessive for some individuals. Cool down periodically and leave the spa if nausea or dizziness occurs" , Provide the correct wording not less than 10 mm high with a 5mm stroke: "Enter and exit the spa slowly, to prevent slipping" , Provide the correct wording not less than 10 mm high with a 5mm stroke: "Do not play or swim near drains or suction devices. Your body, body parts, hair, jewelry and other objects may become trapped and cause injury or drowning. People with long hair should be especially careful" , Provide the correct wording not less than 10 mm high with a 5mm stroke: "Do not enter or remain in a spa if a drain cover or suction fitting is loose, broken or missing. Immediately notify the spa operator" , Provide the correct wording not less than 10 mm high with a 5mm stroke: "No food or beverage except water is permitted within the deck or spa. No glass containers of any kind are permitted within the deck or spa" , Indicate the maximum number of bathers (the lesser of: one person per square metre of surface water OR the load identified by the manufacturer of the spa)
22 jul 2024 · Re-inspection
Sin infracciones

No se registraron infracciones en esta inspección.

18 jul 2024 · Compliance Inspection
Requiere nueva inspección
  • No grave Redacción oficial (en inglés): Manual chemical testing in compliance
    Nota del inspector (en inglés): Not in Compliance: Automatic Sensing Device - Ensure pH, alkalinity, Free Available Chlorine, total chlorine or bromine residuals and water clarity are tested manually one half hour before bathers are admitted, and checked at least every 4 hours during the operating day
  • Grave Redacción oficial (en inglés): Sanitizer levels in compliance
    Nota del inspector (en inglés): Not in Compliance: Maintain Total Bromine between 5mg/L (5ppm) - 10mg/L (10ppm)
  • No grave Redacción oficial (en inglés): Total alkalinity is between 80 mg/L (80 ppm) and 120 mg/L (120 ppm)
    Nota del inspector (en inglés): Not in Compliance: Maintain total alkalinity between 80mg/L (80ppm) and 120 mg/L (120 ppm)
  • No grave Redacción oficial (en inglés): Daily records completed, signed and maintained
    Nota del inspector (en inglés): Not in Compliance: Complete and sign records daily, Automatic sensing device-record Bromine residual – hour before opening & every 4 hours while spa is open, Automatic sensing device- record pH – hour before opening & every 4 hours while pool is open, Automatic sensing device- record alkalinity – hour before opening & every 4 hours while open, Automatic sensing device- record clarity of pool – hour before opening & every 4 hours while open, Record time of day for testing of emergency telephone, Emergency telephone must be tested to confirm that is in operating condition before the pool or spa is opened for use each day
  • No grave Redacción oficial (en inglés): Water facility inaccessible when closed
    Nota del inspector (en inglés): Corrected During Inspection: Ensure there is no access to spa facility when closed

Los registros provienen de Region of Waterloo Public Health (Check It! We Inspect It.). Describen las condiciones en la fecha de la inspección.