May 11, 2026 · Compliance Inspection
Infractions found
  • Non-critical Manual chemical testing in compliance
    Inspector's note: Not in Compliance: Automatic Sensing Device - Ensure pH, alkalinity, Free Available Chlorine, total chlorine or bromine residuals and water clarity are tested manually one half hour before bathers are admitted, and checked at least every 4 hours during the operating day
  • Critical Sanitizer levels in compliance
    Inspector's note: Not in Compliance
  • Critical Premises is operated and maintained free from every condition that may be a potential/immediate health hazard
    Inspector's note: Not in Compliance
May 11, 2026 · Compliance Inspection
Infractions found
  • Non-critical Pool, deck, equipment, sanitary facility and adjoining areas kept in a safe and sanitary manner and free from hazards
    Inspector's note: Not in Compliance: Maintain deck and deck surfaces in a sanitary condition and free from slipperiness
  • Non-critical Manual chemical testing in compliance
    Inspector's note: Not in Compliance: Automatic Sensing Device - Ensure pH, alkalinity, Free Available Chlorine, total chlorine or bromine residuals and water clarity are tested manually one half hour before bathers are admitted, and checked at least every 4 hours during the operating day
Feb 3, 2026 · Compliance Inspection
Infractions found
  • Non-critical Sufficient supply and storage of chemicals and testing devices
    Inspector's note: Not in Compliance: Ensure supply of chemicals are sufficient to operate the pool
Jan 19, 2026 · Re-inspection
No violations found

No infractions recorded at this inspection.

Oct 7, 2025 · Re-inspection
Infractions found
  • Non-critical Other records signed and completed
    Inspector's note: Corrected During Inspection: Ensure water outlet cover inspections are recorded at least once every 30 operating days along with time of day the test was completed and by whom, Ensure ground fault detector is tested and recorded monthly or according to the manufacturer–s instructions, whichever is more frequent
Oct 6, 2025 · Compliance Inspection
Re-inspection required
  • Critical Sanitizer levels in compliance
    Inspector's note: Not in Compliance: Maintain Free Available Chlorine between 0.5mg/L (0.5ppm) - 10mg/L (10ppm)
  • Critical Premises is operated and maintained free from every condition that may be a potential/immediate health hazard
    Inspector's note: Not in Compliance: CLOSE POOL
Jun 25, 2025 · Compliance Inspection
Infractions found
  • Non-critical Total alkalinity between 60mg/L (60ppm) and 180mg/L (180ppm)
    Inspector's note: Not in Compliance: Maintain total alkalinity between 60mg/L (60ppm) - 180mg/L (180ppm)
  • Critical pH is within range of 7.2 to 7.8
    Inspector's note: Not in Compliance: Maintain pH between 7.2 to 7.8
  • Critical All components of the filtration, recirculation, and chemical feed systems are in continuous operation and maintained in proper working order
    Inspector's note: Corrected During Inspection: Ensure automatic sensing device Oxidation Reduction Potential value is not less than 600mV and not greater than 900mV
Mar 26, 2025 · Compliance Inspection
Infractions found
  • Non-critical Manual chemical testing in compliance
    Inspector's note: Not in Compliance: Automatic Sensing Device - Ensure pH, alkalinity, Free Available Chlorine, total chlorine or bromine residuals and water clarity are tested manually one half hour before bathers are admitted, and checked at least every 4 hours during the operating day
Nov 26, 2024 · Compliance Inspection
Infractions found
  • Non-critical Accurate and functioning make-up water meter present
    Inspector's note: Not in Compliance: Ensure minimum 15L/bather of make-up water is added to the pool daily
  • Non-critical Manual chemical testing in compliance
    Inspector's note: Not in Compliance: Automatic Sensing Device - Ensure pH, alkalinity, Free Available Chlorine, total chlorine or bromine residuals and water clarity are tested manually one half hour before bathers are admitted, and checked at least every 4 hours during the operating day
  • Non-critical Daily records completed, signed and maintained
    Inspector's note: Not in Compliance: Automatic sensing device- record Chlorine (free and total) – hour before opening & every 4 hours while pool is open, Automatic sensing device- record pH – hour before opening & every 4 hours while pool is open, Automatic sensing device- record alkalinity – hour before opening & every 4 hours while open, Automatic sensing device- record clarity of pool – hour before opening & every 4 hours while open, Record reading of the make-up water meter daily
Sep 4, 2024 · Compliance Inspection
Infractions found
  • Non-critical Total alkalinity between 80mg/L (80ppm) and 120mg/L (120ppm)
    Inspector's note: Not in Compliance: Maintain total alkalinity between 80mg/L (80ppm) - 120mg/L (120ppm)
  • Non-critical Sufficient supply and storage of chemicals and testing devices
    Inspector's note: Not in Compliance: Ensure testing devices are adequate and sufficient to operate the pool
  • Non-critical Daily records completed, signed and maintained
    Inspector's note: Not in Compliance: Emergency telephone must be tested to confirm that is in operating condition before the pool or spa is opened for use each day